Recommended for low and medium voltage power of 5000 volts. Used primarily in control circuits and for airport lighting. 5KV XLP power cables can be used in conduit, duct and direct buried. The temperature rating is 90C.
Conductor: Stranded bare copper
Insulation: Cross-linked polyethylene (XLP)
Airport Lighting: Sizes meet specs for Federal Aviation Admin per L-824-Type C.
Application: 5KV/8KV power cables are recommended for use as feeder circuits, distribution circuits, and for feeders or branch circuits in commercial and industrial applications. Installed in wet or dry locations or direct buried. 1/0 and larger are CT (Cable tray) rated.The temperature rating is 105°C.
Conductor: Stranded bare copper
Insulation: Ethylene propylene rubber (EPR)
Shield: Copper tape shield
Jacket: PVC Jacket- 100%/ 133%
Flame Test: IEEE 383 70,000 BTU/hr flame test
Color Code: Click here
5KV/8KV power cables are recommended for use as feeder circuits, distribution circuits, and for feeders or branch circuits in commercial and industrial applications. Installed in wet or dry locations or direct buried. 1/0 and larger are CT (Cable tray) rated.
Conductor: Stranded bare copper
Insulation: Ethylene propylene rubber (EPR)- 133% 5KV and 100% 8KV
Shield: Copper tape shield
Jacket: PVC Jacket
Flame Test: IEEE 383 70,000 BTU/hr flame test
25KV/ 35KV power cables are recommended for use as feeder circuits, distribution circuits, and for feeders or branch circuits in commercial and industrial applications. Installed in wet or dry locations or direct buried. 1/0 and larger are CT (Cable tray) rated. The temperature rating is 105C.
Conductor: Stranded bare copper
Insulation: Ethylene propylene rubber (EPR)- 133% 25KV and 100% 35KV
Shield: Copper tape shield
Jacket: PVC Jacket- 100% / 133%
Flame Test: IEEE 383 70,000 BTU/hr flame test
15KV power cables are recommended for use as feeder circuits, distribution circuits, and for feeders or branch circuits in commercial and industrial applications. Installed in wet or dry locations or direct buried. 1/0 and larger are CT (Cable tray) rated. The temperature rating is 105C.
Conductor: Stranded bare copper
Insulation: Ethylene propylene rubber (EPR)- 133% level
Shield: Copper tape shield
Jacket: PVC Jacket
Flame Test: IEEE 383 70,000 BTU/hr flame test
Medium voltage power cables are recommended for use as feeder circuits, distribution circuits, and for feeders or branch circuits in commercial and industrial applications. Installed in wet or dry locations or direct buried.
Conductor: Stranded bare copper
Insulation: Ethylene propylene rubber (EPR)
Armor: Aluminum interlocked armor (AIA). Special order for galvanized steel armor.
Jacket: Yellow PVC Jacket
Color Code: Click here
5KV/8KV power cables are recommended for use as feeder circuits, distribution circuits, and for feeders or branch circuits in commercial and industrial applications. Installed in wet or dry locations or direct buried. 1/0 and larger are CT (Cable tray) rated. The temperature rating is 90C
Conductor: Stranded bare copper
Insulation: Cross-linked polyethylene (XLP)
Shield: Wire shield
Jacket: PVC jacket
15KV power cables are recommended for use as feeder circuits, distribution circuits, and for feeders or branch circuits in commercial and industrial applications. Installed in wet or dry locations or direct buried. The temperature rating is 90C.
Conductor: Stranded bare copper
Insulation: Cross linked polyethylene (XLP)- 133% level
Shield: Wire Shield
Jacket: PVC Jacket
35kV power cables are recommended for use as feeder circuits, distribution circuits, and for feeders or branch circuits in commercial and industrial applications. Installed in wet or dry locations or direct buried. 1/0 and larger are CT (cable tray) rated. The temperature rating is 105C.
Conductor: Stranded bare copper
Insulation: Ethylene propylene rubber (EPR)- 133% level 35kV
Shield: Copper tape shield
Jacket: PVC Jacket
Flame Test: IEEE 1202 70,000 BTU/hr flame test